Introduction: Why is the selection of VRF indoor units so important
In any VRF project, indoor unit selection is a key link in determining the final comfort experience. While outdoor units often get the spotlight for their capacity and system scale, it is the indoor units installed in each room that really affect the perceived temperature, air distribution, noise performance, and operating efficiency of each space. A proper indoor unit can provide a steady supply of comfortable air, maintain low noise operation, and maintain high energy efficiency over the long term.

When the indoor machine is not selected, the problem will quickly appear.The room may be hot and cold, uneven air flow, high noise, increased energy consumption, etc. If there is a deviation in the selection of multiple indoor machines, it will even lead to the imbalance of the capacity ratio of the whole VRF system. It can be seen that understanding how to choose the most suitable indoor machine is an important ability that engineers, consultants, installers and even building owners must master.
This article will explain how to choose the right VRF indoor unit systematically from the three core dimensions of room load, environmental conditions and application types.
Understanding room load: The fundamental logic for indoor unit selection
Room load refers to the heat that needs to be removed or replaced from a room in order to maintain a set room temperature, including cooling load and heat load. The load situation is different in each room because of the huge differences in orientation, structure, purpose and usage habits of different spaces.

A living room with a large expanse of western glass heats up quickly, while a study of the same size facing north may change slowly. A conference room for a dozen people has a significantly higher source of heat than an empty office. Even if the area is the same, each room must be subjected to a separate load judgment due to differences in building materials, insulation, window-to-wall ratios, and personnel activities. Room load is the most fundamental basis for indoor machine selection. Any selection method without load can not ensure long-term comfort and efficient operation.
There are many factors that affect load. The area and floor height of the room will determine the volume of air that needs to be regulated. Rooms facing south or west will have higher heat gain due to stronger sunlight. The larger the glass area and the weaker the thermal insulation, the higher the cooling load tends to be. The number of people, the heat dissipation of lamps, kitchen equipment, and electronic products will bring different degrees of sensible and latent heat to the space.
Because these variables vary greatly in different spaces, indoor machine selection must be based on load analysis of specific rooms, and cannot rely on experience or uniform standards.
The room load not only determines the capacity of the indoor machine, but also affects the type of machine model applied. The bedroom with smaller load is often suitable for wall-mounted or small air duct machine. The living room with large load generally needs a four-way embedded or medium-sized air duct machine. Large areas such as meeting rooms, classrooms, and training spaces may require high static pressure air ducts to ensure adequate air supply. In other words, the load determines the capacity, the capacity determines the type, and the type further affects the airflow distribution and the physical comfort.
Match the capacity of the indoor unit with the room load
After specifying the room load, the next step is to accurately match the indoor machine capacity with the actual demand. VRF selection software usually provides manual selection and automatic selection of two ways. Manual selection is suitable for the case that the detailed load calculation has been completed, and the designer can directly select the corresponding model according to the calculation results. The automatic selection method is more efficient. The software will automatically recommend the most matching indoor machine according to the set design temperature, cooling and heating conditions and the range of optional models, which is very suitable for program selection or early design stage of the project.

The accuracy of capacity matching is crucial.Indoor opportunities with excessive capacity lead to frequent starts and stops, obvious temperature fluctuations, increased noise, and waste of energy consumption at the same time. Indoor units with insufficient capacity will find it difficult to reach the set temperature and run at full load for a long time, which will not only reduce comfort, but also shorten the life of the equipment. The most effective choice is always one that is neither big nor small and can maintain room temperature continuously in stable operation.
The interior design temperature also has a direct impact on the capacity demand. The lower the temperature setting, the higher the demand for cooling capacity. The referenced VRF software allows the designer to manually adjust the indoor and outdoor design temperature, a critical step since temperature settings vary from region to region, from building to building, and from use case to use.
Custom design conditions to ensure that selection based on real application requirements rather than the theoretical value.
Taking common room types as an example, a small room of 10 to 15 square meters generally requires about 2.2 to 2.8 kilowatts of cooling capacity. A restaurant of twenty to twenty-five square meters usually needs five to seven kilowatts. Conference rooms may require eight to twelve kilowatts or more, depending on the number of people and equipment.The above example will help you understand that the capacity choice must depend on the room situation, not just on the square footage calculation.
Environmental conditions: Variables that are often overlooked but extremely important
Many people tend to ignore environmental conditions when selecting indoor machines, but these factors have a great impact on the final effect. The first step is the indoor temperature setting. If the user expects lower room temperatures or uses the system in extreme climates, the design capacity necessarily needs to be increased. The VRF selection software allows for manual adjustment of indoor and outdoor design conditions, which ensures that the selection results are consistent with actual use.
Floor height is also an important factor. The higher the floor height, the larger the air volume, and the required cooling amount will also increase. Such rooms usually require high air volume air duct machines or embedded models with large coverage areas. On the contrary, if the ceiling space is limited, it may not be possible to install the air duct machine or the four-way air outlet model, at this time, the wall hanging machine or vertical style is more suitable.
Noise requirements are especially important in some scenes. For example, bedrooms, hospital wards, libraries, hotel rooms and other spaces require low noise equipment. In contrast, office or commercial Spaces can accept higher air volume and slightly higher noise due to higher background noise. Therefore, according to the requirements of the sound environment of the space, the choice of indoor machine is an important step to ensure comfort.
Indoor installation conditions will also limit the selection of models. Some buildings have limited ceiling space and cannot accommodate large-size air duct machines or embedded models. Older buildings don't even have ceilings, so wall-mounted or floor-mounted models are the best choices. Fully understand the structure and limitations of the room to ensure that the selection meets both performance requirements and construction conditions.
Application type: Different Spaces require different indoor units
Different types of Spaces have completely different requirements for indoor machines. Residential bedrooms usually need quiet, small capacity and soft air supply models, wall-mounted or small air duct machine is a common choice. The living room space is large, and the air flow coverage is wide and the air volume is sufficient, such as the four-way air outlet embedded or medium air duct machine. The open space requires a comprehensive consideration of air volume, air supply direction and air distribution.
The office space pursues uniform air supply and simple visual effects. The four-way air outlet embedded model is very common in the office, because the air flow is evenly distributed and can be embedded in the standard ceiling. If the ceiling space is insufficient, ultra-thin air pipe machine is also a common choice. The office often needs to be controlled independently according to the area, so the indoor machine capacity and model must be in line with the actual functional partition.
Hotels are very concerned about noise and concealment. Ceilingers are particularly common in hotel rooms, as they can be hidden from installation and provide a steady, gentle air supply effect. Each room has a different load, so relying on VRF selection software to automatically match capacity is particularly valuable.
Restaurants and retail settings are often high in calories. The area close to the kitchen especially needs more strong cooling, so the large air volume air duct machine or embedded model is more suitable. Commercial spaces also need to consider the visual design, so it is critical to choose beautiful models that do not affect the display.
Large spaces such as meeting rooms, training classrooms, lecture halls, etc. usually require strong air volume or even multiple indoor machines to be covered together. High carbon dioxide concentrations may occur in densely populated areas, so there is a greater need to pay attention to airflow organization and capacity selection.
Practical steps for selection in VRF projects
Following a clear process for indoor machine selection can improve efficiency and accuracy:
First of all, each indoor machine should be named and ensure that it corresponds to the rooms in the project drawings. Clear naming will reduce errors during the construction and commissioning phase. The next step is to select the model category. Wall-mounted models are suitable for small rooms without hanging space.
The air duct machine is suitable for the space that needs hidden installation or high air volume. Embedded models are common in commercial scenarios and enable uniform airflow distribution. When ceiling space or structure is limited, floor or wall hanging machine may be a better choice.
The third step is to select the cooling and heating capacity according to the load. VRF selection software can often automatically recommend the most suitable model, thereby reducing human error. The fourth step is to set up the indoor temperature condition. The temperature requirements vary from project to project, as do the temperature expectations of residential, office and commercial spaces. The correct temperature setting can ensure that the selection results are more in line with the actual use requirements.
The final step is to confirm that the capacity meets the room load and to consider possible functional changes. For example, the current office may be converted into a conference room in the future, and the load demand will increase significantly. Anticipating these changes in advance will ensure that the VRF system remains stable and efficient into the future.
Common mistakes in indoor unit selection
Common errors in indoor unit selection include selecting models based only on room area and neglecting load calculation, which often leads to systems that fail to meet cooling demand. Another typical mistake is to choose a model with too much capacity, resulting in frequent starts and stops, temperature fluctuations, and high noise. Designers sometimes ignore the effect of layer height on load, which will directly affect the matching accuracy of the model.
Ignoring noise requirements in spaces that need quietness is also a common problem. If the air supply range is not accurately estimated, the room may experience uneven heating and cooling. Using too many different types of indoor units throughout the entire project will also increase the difficulty of management and maintenance. For duct air conditioners, insufficient static pressure can lead to weak air supply and poor physical sensation, thereby affecting overall comfort.

Conclusion: The correct selection of indoor units determines the quality of the project
Indoor machine selection directly determines the temperature, comfort and long-term operating efficiency of each room. Only based on accurate load analysis, reasonable environmental conditions and clear application requirements, can we choose a truly suitable model. VRF selection software plays a key role in this process, which can help designers make scientific judgments based on capacity, temperature, and system ratio. The right indoor unit selection can improve comfort, reduce energy consumption, and ensure that the VRF system continues to operate steadily for many years to come.