FCU HVAC: What a Fan Coil Unit Is and Why It’s Still a Go-To Choice

Category: Blogs

In modern building HVAC design, FCU HVAC system is still a very practical solution to achieve "zone comfort control", which can provide stable cooling and heating experience for different rooms or areas without relying on large-scale air duct system. FCU (Fan Coil Unit) is essentially an end device that uses a fan to push air through a heat transfer coil, and uses cold or hot water in the coil to exchange heat with air, so as to achieve cooling or heating. Due to the strong modular nature of the FCU HVAC scheme, it is widely used in hotels, apartments, office buildings, hospitals, airports, commercial complexes and other scenarios that require "independent control by area and flexible operation by use time".

zero-technologies-modular-vrf-and-fan-coil-units

FCU HVAC: How does the fan coil unit work in real projects

The working logic of FCU HVAC is not complex, but it is very efficient. The unit draws back air from the room, filtered first, and then pushed through the coil by the fan. When the coil is flowing in chilled water, the air temperature is reduced. When hot water flows inside the coil, the air temperature is raised. In the refrigeration process, the water in the air will condense into condensate on the surface of the low temperature coil, collect to the water plate and discharge through the drain pipe. If the site cannot meet the natural gravity drainage conditions, it needs to cooperate with the condensate lifting pump. In the actual project, some FCU HVAC models will directly supply air to the room, and the hidden model will often be connected by a short air duct to return to the air organization. The point is that FCU HVAC usually does not need to lay a large air duct network throughout the building like central air conditioning, but does not mean "no air duct at all".

zero-technologies-fan-coil-unit-working-principle-diagram

Common FCU forms and their respective applicable scenarios

Different building structures and indoor conditions will correspond to different FCU HVAC models. Cassette fan coil is usually installed in the ceiling, and can be multi-direction air supply, common in offices, shopping malls and other open areas. Concealed fan coil units are installed in the ceiling or equipment room, which can hide the equipment body. At the same time, they can achieve a more uniform air supply organization through air outlets. When necessary, short air ducts can also be connected. Exposed fan coil units (floor-standing or ceiling-mounted) are convenient for maintenance and are often used in renovation projects or places with limited ceiling space. The wall-mounted fan coil unit is suitable for the space that cannot be installed in the dark or the ceiling condition is limited. Either way, the core performance of the FCU HVAC ultimately depends on the correct air volume matching, coil configuration, drainage scheme, and control strategy.

zero-technologies-fcu-hvac-system-schematic-diagram

The differences between two-pipe and four-pipe systems, and their impact on comfort

In the design of FCU HVAC system, two and four regulation is often one of the most critical decisions. Both systems typically use the same set of coils for cooling and heating, with the building switching between chilled and hot water supplies in different seasons. It has the advantage of simpler pipelines and lower initial investment, but it is usually not able to meet the needs of different areas at the same time "some to cool, some to heat". The four-control system is equipped with separate coils or loops for cooling and heating, which can achieve more flexible zoning control under changing seasons or complex load conditions, so it is more suitable for hotels, hospitals and integrated buildings with obvious differences in cooling and heating demand. Although the initial investment and complexity of the four-control FCU HVAC system is higher, it can significantly reduce the comfort complaints caused by cold and hot conflicts.

Fresh Air and Air Quality - What Can and Cannot FCU Do

A very important but often overlooked fact is that many FCU HVAC system fan coil mainly deals with indoor return air, rather than actively undertake the "introduction of fresh air" task. This does not mean that the FCU HVAC scheme is incomplete, but rather that the ventilation system has to be planned separately. Many commercial buildings will use DOAS (independent fresh air systems) or fresh air units to centrally process outdoor air, and then the FCU HVAC terminal is responsible for the sensible heat load and temperature control of the room. This makes more sense because the fresh air can be treated centrally and take care of the dehumidification needs, while the FCU HVAC end focuses on zoning comfort. When ventilation design is neglected, IAQ problems such as high CO₂, odor residue, and humidity fluctuations may still occur even if the fan coil is operating normally.

Humidity control and "the air is too dry" are not the same issue

Some people would describe FCU HVAC systems as "drying out the air," but it would be more accurate to say that many FCU HVAC terminals do not have active humidity control capabilities for all operating conditions. When the fan coil is cooled and the coil surface temperature is lower than the dew point, it can indeed produce a certain dehumidification effect. But humidity may not be stably controlled in milder climates, higher cold water temperatures, or different operating strategies. The low indoor relative humidity in the heating season is often more related to the low outdoor air moisture content and the humidity taken away by ventilation, not completely caused by the end equipment. A more reliable approach is to use humidity as a system-level target, through fresh air treatment, dedicated dehumidification strategies, and reasonable control logic to achieve a more stable FCU HVAC comfort experience.

Noise and comfort: good design can make a space quieter

The noise performance of FCU HVAC is often a key concern in scenes with high quiet requirements such as hotel rooms and wards. Noise sources include fan body, air turbulence, structural vibration transmission and installation details. In practice, noise levels can be significantly improved if the FCU HVAC unit is properly selected to operate at low wind speeds most of the time, vibration isolation is performed at installation, and turbulence caused by excessive resistance or sharp curves in the return air path is avoided. The choice of DC/EC motor and steerless speed regulation also generally facilitates smoother operation at partial loads, thus improving the "quiet and comfortable" performance of FCU HVAC.

Control mode, water valve and building control connection: the parts that truly determine the experience

In many cases, the quality of a FCU HVAC system is not only determined by the equipment itself, but by the control strategy. Fan control can be the traditional three speed, can also be stepless speed regulation. Water system control can be switched on and off or adjusted by two-way or three-way valves. The room temperature controller is responsible for setting temperature, wind speed and valve action. For larger projects, the FCU HVAC terminal often needs to be connected to the building automation system to realize centralized monitoring, policy linkage and energy consumption optimization through communication or gateway. Good control can not only reduce temperature fluctuations and improve stability, but also significantly reduce energy consumption under partial loads and provide clearer status and fault information for operation and maintenance.

Selection suggestions: the key to avoiding later problems

For the FCU HVAC system to be truly useful in a project, the selection must go back to the design condition itself, not just the "nominal parameters". Air volume and external static pressure are particularly critical for FCU HVAC forms with concealed or connected tuyere/short air ducts, as any resistance such as tuyere, filter, short air duct, and return air box may reduce the actual air supply effect. The number of coil rows, fin form and anti-corrosion treatment not only affect the capacity, but also affect the performance of the unit under different load and different humidity conditions.Drainage design in FCU HVAC can not be regarded as a trivial matter, the slope is insufficient, the design of the water plate is not reasonable, and the maintenance space is not enough, which may cause leakage or odor. Finally, maintenance convenience determines long-term performance, and easy access to filters, coils, and water valves is often more important than "space saving at first glance."

zero-technologies-multi-zone-fcu-hvac-system-diagram

Maintenance points: the foundation for long-term stable performance

The maintenance of FCU HVAC is not complicated, but it needs to be continuous. The filter should be cleaned or replaced regularly according to the dust load on the site. The water collection tray and drainage pipe should be protected from clogging and mold growth. The coil needs to be cleaned regularly to maintain heat transfer efficiency and reduce the risk of odor. The fan and motor should be observed for abnormal vibration or noise. Water valve and pipeline connection should be checked for leakage and confirm that the action response is correct. If the system is equipped with a condensate lift pump, it is necessary to verify the head capacity and safety switch logic, because condensate treatment problems are one of the common after-sale sources of FCU HVAC.

Which projects are suitable for FCU and which are more suitable for other systems

FCU HVAC is usually a very good choice when projects require strong zoning, large differences in running times, and variable space layouts, especially for hotels, apartments, office buildings, and a large number of renovation projects. However, when the building has a stronger demand for centralized ventilation, unified filtration, and super large space air flow organization, or when it cannot easily access multiple ends for maintenance in the later stage, FCU HVAC may not be the optimal solution. Many modern buildings choose a "combined" strategy: the FCU HVAC end is used for regional temperature control, and the separate fresh air system is used for ventilation and humidity control. This not only retains the flexible and independent control advantages of FCU HVAC, but also makes up for the system-level requirements that the end equipment is not good at bearing.

Conclusion

A truly excellent FCU HVAC system is never "choose a fan coil and finish", but the co-design of end equipment, fresh air strategy, water system piping, drainage scheme and control logic. When these elements are matched in place, FCU HVAC can achieve stable comfort, flexible zoning and efficient operation in a variety of building types.